150,System.IO.IOException: The process cannot access the file 'C:\inetpub\wwwroot\css\ExtFiles\CSS150DB.css' because it is being used by another process. at System.IO.__Error.WinIOError(Int32 errorCode, String maybeFullPath) at System.IO.FileStream.Init(String path, FileMode mode, FileAccess access, Int32 rights, Boolean useRights, FileShare share, Int32 bufferSize, FileOptions options, SECURITY_ATTRIBUTES secAttrs, String msgPath, Boolean bFromProxy) at System.IO.FileStream..ctor(String path, FileMode mode, FileAccess access, FileShare share, Int32 bufferSize, FileOptions options, String msgPath, Boolean bFromProxy) at System.IO.FileStream..ctor(String path, FileMode mode, FileAccess access, FileShare share, Int32 bufferSize, FileOptions options) at System.IO.StreamWriter..ctor(String path, Boolean append, Encoding encoding, Int32 bufferSize) at System.IO.StreamWriter..ctor(String path, Boolean append, Encoding encoding) at System.IO.File.WriteAllText(String path, String contents, Encoding encoding) at MasterPage.getStore() in C:\inetpub\wwwroot\MasterPage.master.vb:line 208 at MasterPage.Page_Init(Object sender, EventArgs e) in C:\inetpub\wwwroot\MasterPage.master.vb:line 18 mason industries SSLFH 2 Deflection Welded Restrained SingleSpring Mounts 100 Series sslfh 2 deflection welded restrained singlespring mounts 100 series | 48WS
 
 
 

Search:

SSLFH - 2" Deflection - Welded Restrained Single Spring Mounts 100 Series

SSLFH - 2" Deflection - Welded Restrained Single Spring Mounts 100 Series

Mason Industries

(click image to enlarge)
Quick Overview
    Equipment shall be installed on resilient mountings designed and rated to resist seismic forces in all directions. The snubber shall be adjustable in the vertical up direction and allow a maximum of 1/4” (6mm) travel in the vertical and horizontal direction before contacting the resilient snubbing collars. Mountings shall have an Anchorage Preapproval “OPA” Number from OSHPD in the state of California attesting to the minimum listed certified Horizontal and Vertical load ratings. All mountings shall have adjusting bolts that are rigidly bolted to the equipment. Spring diameters shall be no less than 0.8 of the compressed height of the spring at rated load. Springs shall have a minimum additional travel to solid equal to 50% of the rated deflection. Mountings shall have a minimum of 2 spring inspection ports. Submittals shall include spring diameters, deflections, and calculations signed by a registered engineer showing that the seismic loads the mountings are to resist have been properly calculated. Mountings shall be type SSLFH as manufactured by Mason Industries, Inc.
Interested in this item or want more information?
Call Mon. through Fri. 8:00 AM - 5:00 PM PST
Phone: 714-573-4083
Email: sales@48ws.com

Can't find what you want? Give us a call and we can help you find it.
Additional Information
Manufacturer: Mason Industries
 