Vexcon Certi-Shine Fusion | 48WS

Ecommerce Websites, Catalogs, and Marketing Services

We Do Not Sell Products

 
 
BROWSE CATEGORIES
 

Search:

Vexcon Certi-Shine Fusion

Vexcon Chemicals

(click image to enlarge)
SKU / Product InfoQuantity
VC-CT-0350
Package 1 Gallon Pail
VC-CT-0365
Package 5 Gallon Pail
 
Quick Overview

    Vexcon Certi-Shine Fusion

    Invisible hole and crack repair treatment. Repair small air holes, aggregate pop-outs, voids, micro cracks, small spider cracks and similar surface imperfections.

Interested in this item or want more information?
Call Mon. through Fri. 8:00 AM - 5:00 PM PST
Phone: 714-573-4083
Email: sales@48ws.com

Can't find what you want? Give us a call and we can help you find it.
Details

CERTI-SHINE FUSION

INVISIBLE HOLE & CRACK REPAIR TREATMENT

DESCRIPTION

CERTI-SHINE FUSION is an advanced, modified silicate concrete repair treatment for Certi-Shine polished concrete floors. Certi-Shine Fusion will repair small air holes, aggregate pop-outs, voids, micro cracks, small spider cracks and similar surface imperfections. While other types of repair materials become brittle and discolor the surface leaving it blotchy looking, Certi-Shine Fusion repairs and blends into the existing color of the concrete yielding a consistent, natural looking floor. Grinding and honing can continue one hour after application due to special accelerators and wetting agents which quickly react with the residual cement and calcium hydroxide in the grind powder. The product is completely compatible with all Certi-Shine polishing systems and extends the gloss and clarity yielding a consistent, natural looking floor.

BENEFITS

  • Fills holes, cracks with same color as concrete
  • Makes repairs invisible
  • Cures in 1 hour for additional grinding
  • Does not prevent the application of silicate densifiers
  • Increases gloss and clarity
  • Yields a smoother, denser surface
  • Compatible with all densifier, stain and dye systems
  • Fills early grinding scratches
  • Does not contain any pore clogging latex

APPLICATION

  • Prior to using Certi-Shine Fusion, apply Certi-Shine Fusion Release, product data sheet # OP230, to the bottom of the grinder and to each set of diamonds being used to install Certi-Shine Fusion. IMPORTANT NOTE: Test area must be done on the floor prior to proceeding. Floor with large amounts of aggregate and less cement paste might not react properly with Fusion. Please contact Vexcon technical service for recommendation for the individual floor.
  • Spray or apply a puddle of Certi-Shine Fusion onto the dry floor evenly in front of grinder @ 50-80grit metal diamonds in quantity which forms a slurry as grinding continues.
  • After using Certi-Shine Fusion while grinding in both directions 90° make sure that you have ground the concrete dry without wet slurry or ridges. Concrete should be allowed to dry for a minimum of one hour. Lightly wash the concrete and vacuum or squeegee dry. This will allow you to examine the floor for any remaining holes or voids, etc.
  • Follow instructions for the application and cleaning above.
  • Typically the existing holes, scratches etc. and any new ones created by grinding @ 100-120 grit will be filled.

TREATING LARGER CRACKS, BUGHOLES OR POPOUTS

  1. Collect grinding powder from initial opening grinds and save for Certi-Shine Fusion LG
  2. See Certi-Shine Fusion LG “Application to Larger Cracks, Bugholes or Pop-outs” section (product data sheet #OP235) for instructions.

HONING

  • If Certi-Shine Clear is being applied, polish at 200 grit resin diamonds.
  • After 200 grit apply Certi-Shine Clear per standard instructions

COVERAGE

100-150 sq.ft./gal. based on porosity of concrete

PACKAGING

Certi-Shine Fusion is available in 55-gallon drums, 5-gallon pails. Contact Vexcon to discuss your customized packaging requirements

SPECIAL NOTES /LIMITATIONS

  • Best results when applied at 50-800 F (10-270 C) slab temperature
  • Cure time will be extended at lower temperatures
  • Keep from freezing
  • Do not wet grind or polish until Certi-Shine Fusion has cured overnight
  • Dry grinding, honing and polishing after 1 hour
  • Proper application of Vexcon material is the responsibility of the installer or user. Telephone consultation and/or field visits by Vexcon personnel are for the sole purpose of making technical recommendations only, and not for providing quality control or supervision on location.

VITAL STATISTICS

Boiling Point(760 mm Hg) 212º F(100º C)
Flash Point NA
Autoignition Temp NA
Pounds/gal 10.5
VOC Zero

HEALTH AND SAFETY

Vexcon MSDS # OP225 is an integral part of the safety and application of our product. Before using this Vexcon product obtain a copy of the MSDS from your distributor or by contacting Vexcon Chemicals.

Additional Information
Manufacturer: Vexcon Chemicals
For More Information on the Vexcon Certi-Shine Fusion, [Click Here] to Link to Manufacturer Web Site
 
Facebook LinkedIn YouTube
 
© 48WS®.com LLC. All Rights Reserved
 
Powered by 48WS.com