    Powerseal 40%

    Premium high solids performance, deep penetration, water base clear water repellent sealer for best protection against salt corrosion, water, wind driven rain, airborne contaminants and freeze thaw cycles.

Interested in this item or want more information?
Call Mon. through Fri. 8:00 AM - 5:00 PM PST
Phone: 714-573-4083
Email: sales@48ws.com

Can't find what you want? Give us a call and we can help you find it.
Details

POWERSEAL 40%

WATER REPELLENT PENETRATING SEALER - BEST PROTECTION

DESCRIPTION

POWERSEAL 40 is a premium high performance breathable, efficient water base clear penetrating water repellent sealer that deeply penetrates into new (14 day minimum) or existing concrete and masonry surfaces. Surfaces treated with PowerSeal 40 have a totally natural appearance. PowerSeal 40 stops the intrusion of water, salts, deicer chemicals, and acid rain, which often result in efflorescence, mildew growth, corrosion, scaling, spalling, surface erosion, and other costly damage to hard surfaces. PowerSeal 40 penetrates into the pores and capillaries of the cement based materials reacting with the moisture and chemicals in the substrate, polymerizing and sealing the pores, which prevents water, chemical and chloride ion penetration. PowerSeal is specially formulated with a reduced evaporation rate so more of the active ingredients react with the substrate rather than evaporate with the solvent or water as with similar products. Material efficiency is increased, making PowerSeal more effective than competitive products

BENEFITS

  • Extends the life of concrete and masonry surfaces
  • Best long term protection against salt corrosion, deicing chemicals, mildew, water, wind driven rain, airborne contaminants, surface spalling from freeze/thaw cycles, and other severe weather conditions
  • Reduces corrosion of rebar and surface erosion in reinforced concrete
  • An effective chloride screen
  • Prolongs the surface life and prevents damage from within by maintaining vapor permeability of concrete
  • Superior water repellency
  • Can be applied to damp surfaces
  • Suitable for alkaline concrete surfaces
  • Water base - safer to use - low odor
  • Does not alter natural surface texture or appearance
  • Keeps substrate cleaner

RECOMMENDED FOR

Engineered for transportation, commercial, industrial, distribution and institutional structures

  • Pre-cast concrete
  • Parking structures
  • Concrete block and CMU
  • Concrete ramps
  • Cast-in-place concrete
  • Median barriers
  • Tunnel walls
  • Brick walls
  • Bridge decks
  • Pavers
  • Other reinforced concrete structures

EXCLUSIVE PROTECTIVE COLLOID EMULSION

PowerSeal water repellents are produced with Vexcon's proprietary protective colloid emulsion technology. This technology prevents premature hydrolysis of the silane with the water used as a carrier in the emulsion. Premature hydrolysis is a process that reduces the effectiveness of water repellents.

PRE-INSTALLATION NOTES

  • A test application is necessary on each surface to be treated to ensure compatibility and desired water repellency. Test areas are also useful in determining final application rate and procedures.
  • If the material in the test area does not fully penetrate due to coatings or inadequately cleaned surface, use one of Vexcon’s cleaners and stain removal products to properly clean the surface prior to application.
  • If a tacky residue remains after 24 hrs, the application rate must be modified. Material which remains tacky on the surface can usually be removed by washing with water or a vinegar solution.
  • Tests should be applied using the same equipment and techniques planned for job application.
  • Overspray can be removed with Certi-Vex? Equipment Cleaner before the solution has dried. Protect non-porous surfaces

SURFACE PREPARATION

  • All caulking, patching, and joint sealants should be installed and fully cured prior to application. Concrete should be properly cured; see Curing Recommendations section.
  • All surfaces must be cleaned free of dust, dirt, surface materials, previous coatings, and contaminants.
  • New concrete normally does not require etching. However, slick trowel finished concrete that has become heavily contaminated with surface dirt, tire marks, oil, etc., during construction may require thorough cleaning and a mild etch using StarSeal EF Safe Etch.
  • Older concrete surfaces should be power washed with high-pressure water and StarSeal Brick & Masonry Cleaner to assure removal of surface dirt, oil and other contaminants; use StarSeal EF Stripper to remove coatings, adhesives and floor waxes.
  • To determine that the concrete is penetrable, perform a water absorbency test by applying water to a representative portion of the prepared surface. A properly prepared surface when dry will immediately absorb clean water without any surface beading effects.

CURING RECOMMENDATIONS

  1. Concrete can be cured with Certi-Vex Envio Cure, an emulsion resin cure, which will dissipate. Allow to dissipate or remove with StarSeal EF Stripper.
  2. Wet Cure

SHORT SPECIFICATION

07 19 16: Low VOC water repellent. VOC content less than 100 grams/liter. Meets or exceeds NCHRP 244 Series IV test, reducing water and salt penetration by minimum 90%. Ten year warranty. Manufactured by Vexcon Chemicals.

PACKAGING

PowerSeal 40 is available in 55 gallon drums and 5 gallon pails. Contact Vexcon directly to discuss your customized packaging requirements

APPLICATION

  • PowerSeal 40 should not be diluted or altered, see Coverage Rates.
  • Apply with low-pressure (20-PSI) airless industrial spray equipment. Sprayer should be fitted with solvent resistant hoses and gaskets.
  • If using brushes or rollers, care should be taken to ensure that enough solution is applied.
  • Treated surfaces should be protected from rain and foot traffic for 4-6 hours following application.
  • Protect from vehicular traffic up to 24 hrs. or until the surface is dry.
  • Allow 5-7 days for the product to fully react before evaluation

HORIZONTAL SURFACES

  • Apply in a single saturating application with sufficient material applied so the surface remains wet for a few minutes before penetration into the surface.
  • Surface residues, pools and puddles should be broomed or brushed out until they completely penetrate into the surface

VERTICAL SURFACES

  • PowerSeal 40 should be applied and absorbed on the substrate to the specified coverage rate.
  • In the case of extremely dense, mirror finish architectural concrete and similar surfaces, it may be necessary to restrict the amount of material by first applying a light mist coat by the procedure listed below in order to prevent surface darkening.
  • Allow the mist coat to penetrate the masonry surface (approximately 3-5 minutes) and apply in the same saturation manner.
  • Apply PowerSeal 40 in a flooding application, from the bottom up with sufficient material applied to provide a 6" to 8" run down below the contact point of the new spray pattern with the surface

COVERAGE RATES/ESTIMATING

Porosity and texture of the surface will affect the amount of material necessary for effective treatment. The following is a guide for estimating total material requirements. Always test on the actual surface to get precise consumption rates

  • Concrete/Horizontal
  • Broom finish125-140 ft2/gal. (3.1-3.5m2/L)
    Smooth Hard Troweled 200-400 ft2/gal. (6.5-11m2/L)
    Older concrete (Porous) 95-140 ft2/gal. (2.4-3.5m2/L)
    Pavers125-140 ft2/gal. (3.1-3.5m2/L)
    Tiles200-250 ft2/gal. (6.5m2/L)
  • Concrete/Vertical
  • CIP or Precast150-200 ft2/gal (3.5-5m2/L)
    Stucco95-140 ft2/gal (2.4-3.5m2/L)
  • Architectural Concrete block
  • Smooth-faced95-140 ft2/gal (2.4-3.5m2/L)
    Split-faced50-100 ft2/gal (1.25-2.5m2/L
    Ground-faced200-250 ft2/gal (5-6.25m2/L)
    Ribbed50-100 ft2/gal (1.25-2.5m2/L

SPECIFICATIONS/COMPLIANCE

  • CSI reference: 03 01 30.51, 03 01 40.51
  • Meets all clean air standards throughout the US & Canada:

VITAL STATISTICS

PH8.5
Flash Point 235°F (113°C)
Boiling Point >400ºF
Autoignition Temp ND
Extinguishing MediaFoams, Dry Chemical, C02, Water fog or spray

SPECIAL NOTES

  • Do not apply to plastic, PVC or rubber
  • Protect all surrounding plant and vegetation with a plastic drop cloth.
  • Surface area should be tested to prevent damage to substrate.
  • If applying out doors or interior hot or dry conditions cover the area with light plastic drop cloth.
  • Do not allow the product to dry on the surface. Keep wet by applying additional material.
  • Do not thin Starseal EF Stripper. It is supplied at the proper consistency for most effective action.
  • If using a brush to apply the product do not apply like a

PACKAGING

Starseal EF Stripper is available in 55-gallon drums, 5-gallon pails and 1-gallon containers. Contact Vexcon to discuss your customized packaging requirements

COVERAGE

Typical application rate is 500-1000 ft2/gal (12.5-25 m2/L) depending on porosity, texture and form material. Conduct a test application to verfy the proper application rate for your use.

HEALTH AND SAFETY

  • Use only with adequate ventilation.
  • If swallowed, do not induce vomiting.
  • Use of gloves, goggles and other protective clothing is advised when using this product.
  • Caution, slippery when applied. Use care when walking

The stripper solution and/or materials may be classified as a hazardous material for purposes of disposal. This material should be kept in a separate container and local federal rules for disposal must be followed. Vexcon MSDS OP140 is an integral part of the safety and application of our product. A short synopsis is provided in this product data sheet. Before using this Vexcon product, it is advisable to obtain a copy of the MSDS from your distributor or by contacting Vexcon Chemicals.